SHAPE PRODUCTS -- SPOT REMOVER -- 6850-01-015-7939
===================== Product Identification ===================== Product ID:SPOT REMOVER MSDS Date:01/01/1987 FSC:6850 NIIN:01-015-7939 === Responsible Party === Company Name:SHAPE PRODUCTS Address:1127 57TH AVE. City:OAKLAND State:CA ZIP:94621 Info Phone Num:804-275-4341 (DGSC-SSH) Emergency Phone Num:800-424-9300 (CHEMTREC) Preparer's Name:DGSC-SSH Chemtrec Ind/Phone:(800)424-9300 CAGE:3D869 === Contractor Identification === Company Name:SHAPE PRODUCTS Address:1127 57TH AVE. Box:City:OAKLAND State:CA ZIP:94621-4427 Country:US Phone:510-534-1186 OR 800-444-0015 CAGE:3D869 ============= Composition/Information on Ingredients ============= Ingred Name:ALIPHATIC PETROLEUM DISTILLATES Fraction by Wt: 95% OSHA PEL:500 PPM ACGIH TLV:100 MG/M3 Ingred Name:OIL-SOLUBLE SURFACE ACTIVE AGENT BY THE ETHOXYLATION OF PETROLEUM DERIVED LINEAR ALCOHOLS IN THE C*11 TO C*15 RANGE. RTECS #:9999999ZZ Fraction by Wt: 5% Other REC Limits:NONE SPECIFIED ===================== Hazards Identification ===================== Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:EYES/SKIN: IRRITATION. INHALATION:LOW DEGREE OF TOXICITY. BREATHING HIGH CONCENTRATIONS OF VAPORS OR MISTS MAY RESUL IN IRRITATION OF THE NOSE AND THROAT AND SIGNS OF NERVOUS SYSTEM DEPRESSION.INGEST ION:LOW DEGREE OF TOXICITY; HOWEVER IT IS AN ASPIRATION HAZARD. DO NOT INDUCE VOMITING.NARCOSIS IN HOIGH CONCENTRATION Explanation of Carcinogenicity:NONE OF THE COMPOUNDS IN THIS PRODUCT IS LISTED BY IARC, NTP, OR OSHA AS A CARCINOGEN. Effects of Overexposure:VAPORS IN HIGH CONCENTRATION ARE ANESTHETIC. OVEREXPOSURE MAY RESULT IN FATIGUE, WEAKNESS, CONFUSION EUPHORIA,DIZZINESS, HEADACHE, DILATED PUPILS, LACRIMATION, NERVOUSNESS, MUSCLE FATIGUE,INSOMNIA, PA RESTHESIA, DERMATITIS, AND PHOTOPHOBIA.EYE/SKIN:IRRITATION. Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS ======================= First Aid Measures ======================= First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING EYELID. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WI SOAP & WATER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ADVICE. INHALATION:REMOVE T O FRESH AIR. GIVE MOUTH-TO-MOUTH RESUSCITATION IF NOTBREATHING. GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE VOMITING. GIVE NOTHING BY MOUTH IF UNCONSCIOUS. GET MEDICAL ATTENTION IMMEDIATELY. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:138F/58.9C Extinguishing Media:USE CARBON DIOXIDE, FOAM, OR DRY CHEMICAL. Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCB & FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER SPRAY TO CO NEARBY CONTAINERS EXPOSED TO FIRE. Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MAY CAUSE PRODUCTI OF HAZARDOUS DECOMPOSITION PRODUCTS. ================== Accidental Release Measures ================== Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION.VENTILATE AND REMOVE WITH INERT ABSORBENT. DIKE AHEAD OF SPILL FOR LATER RECOVERY FOR LARGE SPILLS. ====================== Handling and Storage ====================== Handling and Storage Precautions:CONTENTS ARE FLAMMABLE. KEEP AWAY FROM HEAT, SPARKS, AND OPEN FLAME. DURING USE AND UNTIL ALL VAPORS ARE GONE: KEEP AREA VENTILATED-DO NOT SMOKE. Other Precautions:AVOID BREATHING OF VAPORS. ============= Exposure Controls/Personal Protection ============= Respiratory Protection:WEAR A NIOSH/MSHA APPROVED RESPIRATOR IF VENTILATION DOES NOT MAINTAIN INHALATION EXPOSURES BELOW PEL/TLV. WEAR SELF-CONTAINED BREATHING APPARATUS IF REQUIRED FOR HIGH LEVELS OF CONTAMINATES. Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF THE EXPOSURE IS MAINTAINED BELOW APPLICABLE EXPOSURE LIMITS. Protective Gloves:NEOPRENE OR NATURAL RUBBER GLOVES Eye Protection:PAINT GOGGLES/SAFETY GLASSES AS REQUIRED Other Protective Equipment:INDUSTRIAL-TYPE WORK CLOTHING, HAT AND APRON AS REQUIRED. Work Hygienic Practices:USE WITH ADEQUATE VENTILATION. AVOID BREATHING VAPOR/SPRAY MIST. AVOID CONTACT WITH SKIN & EYES. WASH HANDS AFTER USE. Supplemental Safety and Health MSDS IS GENERATED BY DGSC-SSH. VENDOR IS OUT OF BUSINESS. ================== Physical/Chemical Properties ================== HCC:F4 Boiling Pt:=186.1C, 367.F Vapor Density:>1 AIR=1 Spec Gravity:0.782 Evaporation Rate & Reference:<1 ETHER=1 Solubility in Water:NEGLIGIBLE Appearance and Odor:CLEAR, ALMOST COLORLESS LIQUID; CHARACTERISTIC ODOR Percent Volatiles by Volume:100 ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING AGENTS, STRONG ACIDS, STRONG BASES,SELECTED AMINES. Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES Hazardous Decomposition Products:BY FIRE: CARBON MONOXIDE, CARBON DIOXIDE ==================== Disposal Considerations ==================== Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.