ACE HARDWARE CORP -- 233A111 FIRE STAR RUST STOP PRIMER (GRAY) -- 8010-00N076201
=====================  Product Identification  =====================

Product ID:233A111 FIRE STAR RUST STOP PRIMER (GRAY)
MSDS Date:08/09/1991
FSC:8010
NIIN:00N076201
=== Responsible Party ===
Company Name:ACE HARDWARE CORP
Address:21901 S CENTRAL AVE
City:MATTESON
State:IL
ZIP:60443
Country:US
Info Phone Num:708-720-0600
Emergency Phone Num:708-990-6600
CAGE:ACEHA
=== Contractor Identification ===
Company Name:ACE HARDWARE CORPORATION
Address:21901 SOUTH CENTRAL AVENUE
City:MATTESON
State:IL
ZIP:60443
Country:US
Phone:708-720-0600
CAGE:ACEHA

=============  Composition/Information on Ingredients  =============

Ingred Name:TALC (POWDER), CONTAINING NO ASBESTOS FIBERS; (MAGNESIUM
    SILICATE)
CAS:14807-96-6
RTECS #:WW2710000
Fraction by Wt: 27.5%
OSHA PEL:20 MPPCF Z-3
ACGIH TLV:2 MG/M3 RDUST

Ingred Name:IRON (III) OXIDE; (RED IRON OXIDE)
CAS:1309-37-1
RTECS #:NO7400000
Fraction by Wt: 4.9%
OSHA PEL:10 MG/M3 (FE)
ACGIH TLV:5MG(FE)/M3FUME

Ingred Name:PHOSPHORIC ACID, ZINC SALT (2:3); (ZINC PHOSPHATE)
    (MODIFIED)
CAS:7779-90-0
RTECS #:TD0590000
Fraction by Wt: 7.4%
OSHA PEL:15 MG/M3 (MFR)
ACGIH TLV:10 MG/M3 (MFR)

Ingred Name:STODDARD SOLVENT; (MINERAL SPIRITS)
CAS:8052-41-3
RTECS #:WJ8925000
Fraction by Wt: 17.4%
OSHA PEL:500 PPM
ACGIH TLV:100 PPM

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (MINERAL SPIRITS)
CAS:64742-47-8
RTECS #:OA5504000
Fraction by Wt: 15.1%
OSHA PEL:500 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:ETHANOL, 2-PROPOXY-; (2 PROPOXYETHANOL)
CAS:2807-30-9
RTECS #:KM2800000
Fraction by Wt: 0.7%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:ETHYL ALCOHOL
CAS:64-17-5
RTECS #:KQ6300000
Fraction by Wt: 0.2%
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF EYES, SKIN AND
    RESPIRATORY SYSTEM MAY OCCUR ON OVEREXPOSURE. MAY ALSO CAUSE
    NERVOUS SYSTEM DEPRESSION. SIGNS AND SYMPTOMS:HDCH, DIZZ, NAUS &
    LOSS OF COORD ARE INDICATIONS OF EXCESS IVE EXPOS TO VAPS/SPRAY
    MISTS. CHRONIC:RPTS HAVE ASSOC RPTD & PRLNGD OCCUP OVEREXP TO SOLVS
    W/PERM BRAIN & NERV SYS DMG.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:INGESTION:CALL MD IMMEDIATELY . INHALATION:REMOVE FROM
    EXPOSURE. RESTORE BREATHING. KEEP WARM AND QUIET. SKIN:WASH
    AFFECTED AREA THOROUGHLY WITH SOAP AND WATER. EYES:FLUSH WITH LARGE
    AMOUNTS OF	WATER FOR AT LEAST 15 MINUTES. GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:105F,41C
Lower Limits:0.9%
Extinguishing Media:FOR DRY SOLIDS USE WATER, FOAM, CO*2, DRY
    CHEMICALS.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
    WATER MAY BE USED TO COOL CLSD CNTNRS TO PVNT PRESS BUILD-UP & POSS
    AUTO IGNIT/EXPLO WHEN EXPOSED TO (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
    FROM HEAT, ELEC EQUIP, SPKS & OPEN FLAME. HEAT MAY CAUSE PRESS
    BUILD-UP IN CLSD CNTNRS. WATER MAY BE USED TO COOL.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE SOURCES OF IGNITION. VENTILATE AND
    REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CONTENTS ARE COMBUST. KEEP AWAY FROM
    HEAT & OPEN FLAME. USE APPRVD BONDING & GROUNDING PROCEDURES.
    TRANSFER ONLY TO APPROVED, PROPERLY MARKED CNTNRS.
Other Precautions:KEEP OUT OF REACH OF CHILDREN. INTENTIONAL MISUSE BE
    DELIBERATELY INHALING THE CONTENTS CAN BE HARMFUL OR FATAL.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:PROPERLY FITTED ORGANIC VAPOR/PARTICULATE
    RESPIRATOR APPROVED BY NIOSH.
Ventilation:LOCAL EXHAUST:PREFERABLE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH AND DELUGE
    SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:EXTREME HEAT.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:308F,153C
Vapor Density:HVR/AIR
Spec Gravity:1.22 (H*2O=1)
Evaporation Rate & Reference:SLOWER/ETHER (BUAC=1)
Appearance and Odor:RED OXIDE PIGMENTED PRIMER WITH SOLVENT ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY. DO NOT
    INCINERATE CLOSED CONTAINERS. DISPOSE OF IN ACCORDANCE WITH
    FEDERAL, STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.